Buy today - ships today. Original, high quality Frigidaire Room Air Conditioner Parts and other parts in stock with fast shipping and award winning customer service. After destroying our old air conditioner by dropping it out the window, we picked up some heavy duty support brackets to more easily and safely install the replacement. Buy GE air conditioner parts to repair your GE air conditioner at PartSelect Appliance Parts. Great prices on all GE parts you need to help you repair your air.
ARCTIC KING WINDOW/WALL TYPE ROOM AIR CONDITIONER USER MANUAL Pdf Download. Meijer. com WINDOW/WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference. Meijer. com Producto.. Meijer. com 1 8. 66 7 4. Meijer. com CONTENTS 1. SAFETY PRECAUTIONS....... Air conditioner refrigerant has become a hot topic due to its effect on the ozone layer of our earth. The Montreal Protocol requires the phase out of CFC by 1995 and. Window mounted air conditioners from Frigidaire come in a variety of types and sizes. From compact to heavy duty, learn more about our window ACs today. Buy commercial and residential HVAC and AC parts online. We sell furnace, air conditioning, heat pump, motors, coils, compressors, & thermostats parts for sale. IMPORTANT SAFETY INSTRUCTIONS ..... NORMAL SOUNDS ........ AIR CONDITIONER FEATURES ..... INSTALLATION INSTRUCTIONS...... CARE AND CLEANING ....... Meijer. com Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury. Meijer. com ! CAUTION Do not clean the air Ventilate the room well when When the air filter is to be removed, do not touch the conditioner with water. It may cause an injury. Water may enter the unit and An oxygen shortage may occur. Meijer. com IMPORTANT SAFETY INSTRUCTIONS For your safety WARNING NOTE The power supply cord with Do not store or use gasoline or other flammable vapors and liquids this air conditioner contains a current in the vicinity of this or any other appliance. Unit may vibrate and make noise because of poor wall or window construction or incorrect installation. Sound of Rushing Air At the front of the unit, you may hear the sound of rushing air being moved by the fan.. Meijer. com AIR CONDITIONER FEATURES(CONTINUED) NOTE: The following instructions represent the Unit Controls, the same instructions can be used for the Remote Control. TO TURN UNIT ON: Auto Auto Cool High Mode DO THIS: Press the On/Off button. Follow Energy On/Off Saver TO CHANGE TEMPERATURE SETTING.. Meijer. com AIR CONDITIONER FEATURES(CONTINUED) TO SELECT THE NOTE: OPERATING MODE: To choose operating mode, press the Mode button. Each time you press the button, a mode is selected in a sequence that goes from Auto, Cool, Dry to Fan. The indicator light besides will be illuminated and remained on once the mode is selected. Meijer. com AIR CONDITIONER FEATURES(CONTINUED) TIMER: AUTO START/ STOP FEATURE: NOTE: First press the Timer button, the indicator light besides word On illuminates. Keep cool in the heat with our line of built-in and in-window air conditioners, and see how our energy star qualified models can help keep your power bill low. It indicates the Auto Start program is initiated. Temp Temp Press or hold the Left arrow or Right arrow to change the Auto time by 0. Timer Timer.. Meijer. AIR CONDITIONER FEATURES(CONTINUED) NOTE: FOLLOW ME FEATURE: This feature can be activated from the remote control ONLY. The remote control serves as a remote thermostat allowing for the precise temperature control at its location. Auto Auto To activate the Follow Me feature, point the remote Cool Light flashing control towards the unit and press the Follow Me.. Meijer. com INSTALLATION INSTRUCTIONS Your air conditioner is designed to install in standard double hung windows with opening widths of 2. See Fig. 1). Lower sash must open sufficiently to allow a clear vertical opening of 1. Side louvers and the rear EX ERIOR of the AC must have clear air space to allow enough airflow OFFSET.. Meijer. com Fig. B C: Align the hole in the top rail with those in the Fig. C top of the unit as shown in Fig. B D: Secure the top rail to the unit with the 3/8 Screws as shown in Fig. C. NOTE: For safety reasons, all four(4) screws MUST be securely fastened. Meijer. com Fig. 4 C. Once the panel has been installed on the side of the cabinet, make sure it sits securely inside the frame channel by making slight adjustments. Slide the top and bottom ends of the frame into the top and bottom ends of the frame into the top and bottom rails of the cabinet. Meijer. com Drive 3 / 4 (1. Fig. 9 holes into window sash (Fig. To secure lower sash in place, attach right angle sash lock with 3 / 4 (1. Fig. 1. 1). Fig. 1. Fig. 1. 1 Fig. 1. Cut foam seal and insert in the space between the upper and lower sashes (Fig. Meijer. com.. Meijer. TROUBLESHOOTING TIPS Before calling for service, review this list. It may save you time and expenditure. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance. Problem Solution Wall plug disconnected. Push plug firmly into wall outlet. Air conditioner does not start House fuse blown or circuit breaker tripped. Meijer. com Problem Solution Unit removing large quantity of moisture from humid room. This is normal during Water dripping excessively humid days. OUTSIDE when unit is cooling. Remote control not located within range. Place remote control within 2. Remote Sensing radius of the front of the unit.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
August 2017
Categories |